· Clamp-on transducer
· Insertion wetted transducer
· Flow-cell transducer
· Wiring diagram
 
 Current Position: Home -> Product -> Separate fixed flowmeter -> Flow-cell transducer
Flow-cell transducer

Articulate type transducer        PI-type transducer          Standard pipe transducer

Technical parameters

Articulate type

PI-type

Standard pipe

Main unit

Integrative type ,wall-mount, transmission,module

Integrative type ,wall-mount, transmission ,module,water meter

Pipe size

DN25-DN80mm

DN15-DN40

DN50-DN1000

Material

stainless steel

carbon steel(stainless steel is optional)

Frequency

1MHZ

Connection

articulate type

flange type

Application of temperature

  -40℃-160℃

Calibration

  Calibrate with the main unit

Protection class

  IP68(can work in water, and water depth≤3 meter)

Dimension

  refer to the following table

Nominal pressure

  refer to the following table

Liquid types

  Water,sea water.waste water,chemical liquids,oil,crude oil,alcohol,beer,etc.

Suspension concentration

  ≤2000ppm,may contain very small amount of air bubbles.

Transducer cable

  shielded transducer cable,can be extended to 500 meter×2,contact the manufacturer for longer cable requirement.

  Articulate type

Nominal diameter(mm)

Rated pressure(Mpa)

Articulate dimension

Pipe material

L

H

D

C

25

4.0

300

282

51

19

Stainless steel

40

300

300

74

23

50

300

310

84

24

65

350

330

100

28

80

400

345

114

30


  PI –type dimension/Standard-pipe dimension

Nominal diameter(mm)

Rated pressure(Mpa)

PI-type transducer

Standard-pipe transducer

Flange dimension(mm)

L1

L2

D

D1

D2

f

N-Φ

Flange thickness

15

2.5

320

 

95

65

46

2

14×4

14

20

360

 

105

75

56

2

14×4

16

25

390

 

115

85

65

3

14×4

16

32

450

 

140

100

76

3

18×4

18

40

500

 

150

110

84

3

18×4

18

50

1.6

 

200

165

125

99

3

18×4

20

65

 

200

185

145

118

3

18×4

20

80

 

225

200

160

132

3

18×8

20

100

 

250

220

180

156

3

18×8

22

125